Hi, 

I'm in the process of replacing my aging firewalls (Checkpoint) with Sun 
V210s. And I wanted to test a disaster recovery scenario using an 
identical (spare) V210.

Here's the setup : 

BoxA
V210 with 2 36Gb disks
Solaris 9 64-bit Core install
Two filesystems : / and /var
The disks are mirrored using SVM.
Networker Client 7.1
Checkpoint Firewall Software

I backuped BoxA (using the All save set) to my Networker server (7.1 on 
W2K3) with no problems.

I took BoxB, which was identical to BoxA, minus the Checkpoint software 
and did this :
Renamed it to BoxA, and gave it the same ip address.
Took the configuration card of BoxA and put it into the "new" BoxA (BoxB).
Recovered with : recover -a -f / /var
The recover went well, so I issued a "reboot"

Now the new boxA starts booting Solaris 9, and then panics (disque0 is my 
nvalias for HD0):

---
Boot device: disque0  File and args:
SunOS Release 5.9 Version Generic_112233-11 64-bit
Copyright 1983-2003 Sun Microsystems, Inc.  All rights reserved.
Use is subject to license terms.
Cannot mount root on /pseudo/md@0:0,0,blk fstype ufs

panic[cpu0]/thread=140a000: vfs_mountroot: cannot mount root

0000000001409970 genunix:vfs_mountroot+70 (0, 0, 0, 200, 14577e0, 0)
  %l0-3: 000000000144b400 000000000144b400 0000000000002000 
0000000001498f50
  %l4-7: 0000000001496800 0000000001411c30 000000000144bc00 
000000000144ec00
0000000001409a20 genunix:main+98 (1409ba0, f0059c40, 1409ec0, 34b0fd, 
2000, 500)
  %l0-3: 0000000000000001 0000000000000000 0000000001412d60 
0000000078002000
  %l4-7: 000000000140a000 000000000034c000 000000000149ef40 
0000000001064228

skipping system dump - no dump device configured
rebooting...
---

I fscked both partitions / & /var with no luck...

This is the first time I'm dealing with software raid and SVM... so I'm 
kinda lost... any special steps when recovering / ? Any files to exclude ? 
Should I break the mirror before restoring ?

Thanks, 



Alexandre Déry
Technicien, SCSA, CCNA
Direction des services d'inforoute
1500-E, rue Jean-Talon Nord 1er étage
Sainte-Foy (Québec) G1N 4T6
Téléphone: (418) 646-9273
Télécopieur: (418) 528-0418

--
Note: To sign off this list, send a "signoff networker" command via email
to listserv AT listmail.temple DOT edu or visit the list's Web site at
http://listmail.temple.edu/archives/networker.html where you can
also view and post messages to the list.
=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=

<Prev in Thread] Current Thread [Next in Thread>