On Wed, 14 May 2003 12:29:38 +0200, Girot, Jean-Pierre <Jean-
Pierre.Girot AT FR.MTI DOT COM> wrote:

>Where do you find this variable NSR_DEV_TAPE_FILE_SIZE_LTO_ULTRIUM ?
>
>I know this variable NSR_DEV_BLOCK_SIZE_LTO_ULTRIUM for setting the block
size for the tape drive

The FILE_SIZE variables control how often the drive writes an EOF marker.
If these are written too often it will have an adverse effect on
throughput. The NetWorker defaults for LTO and a bit too low, so it is wise
to change this upwards. Making it too high can cause slow tape positioning
for restores, but the value suggested here is pretty good.

--