Networker

Re: [Networker] SDLT full prematurely

2002-08-25 22:45:59
Subject: Re: [Networker] SDLT full prematurely
From: Lee Hwan Meng <hwanlee AT SOFTHOME DOT NET>
To: NETWORKER AT LISTMAIL.TEMPLE DOT EDU
Date: Sun, 25 Aug 2002 22:49:14 -0400
Yes, we are on SAN.

I am not certain that our tape drive(s) cause this, because everytime this
occurs it happens on a different drive. Unless of course all the drives are
faulty, which is a possibility :-(

How do you detect a SCSI bus reset?

Thanks for your comments.



On Sun, 25 Aug 2002 20:12:41 +0800, k0s5 <k0s5 AT YAHOO DOT COM> wrote:

>At 8/25/2002 01:07 PM, Lee Hwan Meng wrote:
>>Hi
>>
>>Did a search through the archive and realise quite a few experienced the
>>above.
>>
>>Well, I did now, and has opened a case with Legato.
>>
>>Anyone willing to share his/her resolution?
>>
>>I will post mine when there is.
>
>Are you on SAN environment?
>Recently we had the same problem on STK9840.
>It turn out that one of the tape drive faulty, and cause a SCSI bus reset
>every now and then
>It caused the Legato session to be terminated, and the media is marked full
>Take a look at the hardware, cabling etc
>
>
>cheers - han
>
>--
>Note: To sign off this list, send a "signoff" command via email
>to listserv AT listmail.temple DOT edu or visit the list's Web site at
>http://listmail.temple.edu/archives/networker.html where you can
>also view and post messages to the list.
>=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=

--
Note: To sign off this list, send a "signoff" command via email
to listserv AT listmail.temple DOT edu or visit the list's Web site at
http://listmail.temple.edu/archives/networker.html where you can
also view and post messages to the list.
=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=