[Bacula-users] Relationship between autochanger slot number and Pool Max Vol?
2016-02-14 18:38:13
I am setting a up a new Bacula 7.4 system and have run into an issue
that I do not understand.
I have a 10 slot autochanger that I have been using since the 5.0.x days
through to 7.0.x. I cannot remember when I last did a clean install
though. Everything has been upgraded over time, so I am not sure when
this became an issue. It could have been an issue all along and I have
just forgotten.
In the 10 slot auto changer I have 4 daily volumes (from the
P-Tape-Daily pool), 4 weekly volumes (from the P-Tape-Weekly pool) and 2
monthly volumes (from the P-Tape-Monthly pool).
On the existing 7.0.5 system the volumes are configured in the catalogue
as being in the autochanger slots as follows:
P-Daily-Tape-001 1
P-Daily-Tape-002 2
P-Daily-Tape-002 3
P-Daily-Tape-002 4
P-Weekly-Tape-001 5
P-Weekly-Tape-002 6
P-Weekly-Tape-003 7
P-Weekly-Tape-004 8
P-Monthly-Tape-001 9
P-Monthly-Tape-001 10
Each Pool has Maximum Volumes set as follows:
P-Tape-Daily 4
P-Tape-Weekly 4
P-Tape-Monthly 2
The same configuration is intended for the new 7.4 system.
To that end, on the new system I have labelled all the tapes and am now
trying to set the autochanger slot for each volume with the update
command in bconsole. The Daily-Pool volumes all updated successfully,
but when I go to do the P-Tape-Weekly volumes I get
*update volume=P-Tape-Weekly-001 slot=5
Invalid slot, it must be between 0 and Maximum Volumes=4
I do not understand what the Pool Maximum Volume setting has to do with
the autochanger slot number. I have confirmed that it is the
P-Tape-Weekly Pool Maximum Volumes causing the issue by increasing it to
8. I can now change the slots for the P-Tape-Weekly volumes to 5-8 as
required. Once the slots have been changed I can change the Maximum
Volumes back to 4 and everything works as it should. At least I think
it does. Still doing some testing.
Same thing for P-Tape-Monthly except Maximum Volumes needs to be 10.
Is this a bug or have I been something wrong all this time?
Regards
Mike
------------------------------------------------------------------------------
Site24x7 APM Insight: Get Deep Visibility into Application Performance
APM + Mobile APM + RUM: Monitor 3 App instances at just $35/Month
Monitor end-to-end web transactions and take corrective actions now
Troubleshoot faster and improve end-user experience. Signup Now!
http://pubads.g.doubleclick.net/gampad/clk?id=272487151&iu=/4140
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- [Bacula-users] Relationship between autochanger slot number and Pool Max Vol?,
Brady, Mike <=
|
|
|