Hi All,
I have a ML6000 that stopped to work after a firmware upgrade to lastest version available (ML6000 Firmware 636G.GS003)
After that I stopped to be able to use mtx commands on my library. My machine is connected via SAS cable with it and still detects the ml6000:
root:~# lsscsi -g
[1:0:0:0] tape IBM ULTRIUM-TD5 D2A6 /dev/st0 /dev/sg3
[1:0:1:0] tape IBM ULTRIUM-TD5 D2A6 /dev/st1 /dev/sg4
[1:0:1:1] mediumx ADIC Scalar i500 636G /dev/sch0 /dev/sg5
I still get tape info:
root:~# tapeinfo -f /dev/sg3
Product Type: Tape Drive
Vendor ID: 'IBM '
Product ID: 'ULTRIUM-TD5 '
Revision: 'D2A6'
Attached Changer API: No
SerialNumber: 'F0A2BD3000'
MinBlock: 1
MaxBlock: 8388608
SCSI ID: 0
SCSI LUN: 0
Ready: no
But can't get library info:
root:~# mtx -f /dev/sg5 status
mtx: Request Sense: Long Report=yes
mtx: Request Sense: Valid Residual=no
mtx: Request Sense: Error Code=70 (Current)
mtx: Request Sense: Sense Key=Illegal Request
mtx: Request Sense: FileMark=no
mtx: Request Sense: EOM=no
mtx: Request Sense: ILI=no
mtx: Request Sense: Additional Sense Code = 49
mtx: Request Sense: Additional Sense Qualifier = 00
mtx: Request Sense: BPV=no
mtx: Request Sense: Error in CDB=no
mtx: Request Sense: SKSV=no
INQUIRY command Failed
Any clue? Everything was working fine before the firmware upgrade.