Bacula-users

Re: [Bacula-users] What might prevent auto-recycling?

2013-08-01 10:03:33
Subject: Re: [Bacula-users] What might prevent auto-recycling?
From: Martin Simmons <martin AT lispworks DOT com>
To: bacula-users AT lists.sourceforge DOT net
Date: Thu, 1 Aug 2013 14:58:57 +0100
>>>>> On Wed, 31 Jul 2013 15:34:50 -0400, Michael Stauffer said:
> 
> Hi,
> 
> I had some jobs stall b/c of no volumes available for recycling. But there
> were two volumes in the pool (Differential) that were last written to
> beyond the 7 day volume retention period. Volumes in the pool are set to
> recycle. Below is the info on volumes and the Differential pool. As far as
> I can tell, the pool and volumes are properly setup for automatic recycling
> after 7 days.
> 
> Why might volumes L50023 and L50024 not been automatically recycled?

You probably need to use a 6 day volume retention period rather than 7,
because the last written time is the end of the job, not the start.

__Martin

------------------------------------------------------------------------------