Re: [Bacula-users] sometimes the mtx gives some errors
2012-10-25 16:27:28
Zitat von warley <bacula-forum AT backupcentral DOT com>:
> Hi guys!
>
> Sometimes the mtx gives some errors, like this one:
>
> root@server1:~# mtx -f /dev/sg2 status
> Storage Changer /dev/sg2:1 Drives, 8 Slots ( 0 Import/Export )
> Data Transfer Element 0:Empty
> Storage Element 1:Full :VolumeTag=000001L5
> Storage Element 2:Full :VolumeTag=000002L5
> Storage Element 3:Full :VolumeTag=000003L5
> Storage Element 4:Full :VolumeTag=000004L5
> Storage Element 5:Full :VolumeTag=000005L5
> Storage Element 6:Full :VolumeTag=000006L5
> Storage Element 7:Full :VolumeTag=000007L5
> Storage Element 8:Full :VolumeTag=000008L5
> root@server1:~# mtx -f /dev/sg2 load 6 /dev/st0 0
Hello
Not sure if this will yield your problem but the manual recommend to
use the "non-rewinding" device eg. /dev/nst0 instead of /dev/st0, see
http://www.bacula.org/5.2.x-manuals/en/problems/problems/Testing_Your_Tape_Drive.html
Regards
Andreas
------------------------------------------------------------------------------