I just upgraded from 5.0.2 to 5.2.2 in the hope that the bug fixes solve a
persistent problem that we've been having (for previous reports and more
details, see [1]).
Unfortunately, the problem still exists, occurs frequently, and causes backups
to be very unreliable.
In short, bacula will call mtx to load a tape into the correct drive in our
changer, but then does not mount the tape. The backup hangs while waiting for
the tape to be loaded, and bacula gives the message:
Please mount Volume "004083" or label a new one
The tape is assigned to the correct pool, in the correct drive, has been used
before (ie., it has been labeled by bacula), and is in the Append state.
Issuing "mount" from within bconsole produces the error that the device is
"open but no Bacula volume is mounted."
Unloading the tape from outside bacula (with mtx), then reloading the tape,
running "update slots", and then "mount" from within bconsole causes bacula to
correctly recognize the presence of the tape and continue the backup.
Are there any suggestions?
Thanks,
Mark