Re: [Bacula-users] Bacula and Dell Powervault 124T
2011-08-04 03:23:47
== Autochanger test ===
>
> 3301 Issuing autochanger "loaded" command.
> Nothing loaded in the drive. OK.
> 3303 Issuing autochanger "load 1 0" command.
>
> It just sits there doing nothing, I guess it is supposed to remove the tape
> from the drive and put the tape from slot 1 into the drive but that doesn't
> seem to happen
I've been using a 124T with Bacula for a little more than a year now.
I noticed that right after the powering on and every time a tape has
been accessed the library has a certain tendency to reply with garbage
to the first changer command it gets; I don't know if it's my particular
unit/setup or if other 124Ts do that.
I never got down to debugging the issue; adding a
${MTX} -f ${ctl} status >/dev/null 2>&1
before every mtx invocation in the mtx-changer script got it working
with Bacula.
HTH,
Andrea
------------------------------------------------------------------------------