Re: [Bacula-users] Bacula crashing after move and upgrade
2010-11-22 09:38:59
Timo Neuvonen wrote:
>> 1. Bacula recognizes the drives but is not reading the changer
>> correctly. When trying to run "update slots" it claims to have 0 slots:
>> 3306 Issuing autochanger "slots" command.
>> Device "Autochanger" has 0 slots.
>> No slots in changer to scan.
>
>
> I think the typical reason causing this is that the storage daemon running
> as bacula:disk does not have write permission to changer device (propably
> /dev/sg...)
This also happens when the changer isn't ready.
Also, for some reason some changers claim to have wrong numbers of
slots/drives at the first MTX command after tapes are inserted/removed.
I discard the first MTX in update scripts which call updateslots for
thie reason.
------------------------------------------------------------------------------