Bacula-users

Re: [Bacula-users] Autochanger weakness

2010-09-06 08:32:35
Subject: Re: [Bacula-users] Autochanger weakness
From: Dan Langille <dan AT langille DOT org>
To: Richard Scobie <richard AT sauce.co DOT nz>
Date: Mon, 6 Sep 2010 08:06:21 -0400
On Sep 5, 2010, at 11:03 PM, Richard Scobie <richard AT sauce.co DOT nz> wrote:

> Unless I have missed something, it appears that if you have an 
> autochanger full of tapes and it becomes unavailable for whatever reason 
> - say the PSU fails, there is no way of accessing the tapes in another 
> drive, as the system thinks are still loaded in the library and will not 
> allow a restore when mounted in another drive, due to "update slots" not 
> being able to be run.
> 
> Surely if a tape is mounted in a drive and the label is read, this 
> should become the new location for this tape?

Are you issuing a mount command after inserting the tape into the other drive?

-- 
Dan Langille
http://langille.org/


------------------------------------------------------------------------------
This SF.net Dev2Dev email is sponsored by:

Show off your parallel programming skills.
Enter the Intel(R) Threading Challenge 2010.
http://p.sf.net/sfu/intel-thread-sfd
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users