Usually you need to complete 1st backup and only after completion this backup
JBB started to be used.
Grigori G. Solonovitch
Senior Technical Architect
Information Technology Bank of Kuwait and Middle East http://www.bkme.com
Phone: (+965) 2231-2274 Mobile: (+965) 99798073 E-Mail: G.Solonovitch AT bkme
DOT com
Please consider the environment before printing this Email
-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf Of
Mehdi Salehi
Sent: Sunday, January 17, 2010 11:04 AM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: [ADSM-L] JBB problem
Hi,
When I use incremental backup of drive e:\ in a windows XP system it does
not use journaling:
1- TSM Journal Engine is configured just for drive e: using B/A client GUI
and Journal database is set to D:\journalDB
2- tsmjbbd.ini is updated with the following stanzas:
[JournaledFileSystemSettings.E:\]
JournalDBSize=0x00000000
JournalDir=d:\journalDB
NotifyFilter=0x0000011f
3- windows is restarted
4- TSM Journal Service is running in Windows services
5- There are two files in D:\journalDB called tsmE__.jdb.jbbdb and
tsmE__.jdbInc.jbbdb each 3KB in size
6- dsmc e:\ -subdir=yes
7- tsmE__.jdb.jbbdb and tsmE__.jdbInc.jbbdb each are still 3KB
8- Some files are copied other partitions to drive E:\
9- tsmE__.jdb.jbbdb and tsmE__.jdbInc.jbbdb each are still 3KB
10- "dsmc e:\ -subdir=yes" does not use journal database as it checks all
files during backup (ANS1898I)
11- jbberror.log is empty
What could be the problem?
Thanks
Please consider the environment before printing this Email.
________________________________
"This email message and any attachments transmitted with it may contain
confidential and proprietary information, intended only for the named
recipient(s). If you have received this message in error, or if you are not the
named recipient(s), please delete this email after notifying the sender
immediately. BKME cannot guarantee the integrity of this communication and
accepts no liability for any damage caused by this email or its attachments due
to viruses, any other defects, interception or unauthorized modification. The
information, views, opinions and comments of this message are those of the
individual and not necessarily endorsed by BKME."
|