ADSM-L

Re: STK Library L700 and ACSLS

2007-02-02 09:24:47
Subject: Re: STK Library L700 and ACSLS
From: Matthias Feyerabend <M.Feyerabend AT GSI DOT DE>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Fri, 2 Feb 2007 15:24:08 +0100
Firmware on IBM LTO1 is 4561, on IBM LTO2 4770. This is the latest
firmware version STK provided us, maybe there are newer versions now
available. I will check that with STK.

I know that we really dont need ACSLS to have only TSM on the library,
even with several servers.
Discussing the "Wait for rewind failed" problems with STK, one of them
mentioned we should move to ACSLS, what means investment of money and time.
I have some vague glance of hope, some error recovery in ACSLS is better
and  will stop getting these errors. ???

Matthias

Richard Sims wrote:

> This thread is dwelling on ACSLS, but is that actually a problem 
> solution?  What if the problem is that the library/drive is failing 
> to wait long enough for the rewind of a high-capacity tape, and 
> considers it "stuck in the drive" because it's not out of there in 
> the allotted time?  That kind of thing is fixed by drive firmware.  
> So, see if your firmware is up to date.
>
>    Richard Sims
>
> On Feb 2, 2007, at 7:09 AM, Matthias Feyerabend wrote:
>
>> Hello,
>>
>> to clarify:
>>
>> We are not yet using ACSLS, but considering to use it in future to
>> overcome errors we get permanently , once twice  a week.
>> Our libraries are connected as SCSI libraries over the SAN with  TSM,
>> one
>> server is library manager, the other servers library clients.
>>
>> My question is, is there some hope or even own experience, that
>> switching to ACSLS will overcome the errors we see at present ( FSC
>> x3e24 for example).
>>
>> Matthias
>>
>>
>> Ibán Bernaldo de Quirós y Márquez wrote:
>>
>>> Hello Matthias,
>>>
>>> I am doing something similar... I am installing 3 TSM servers that
>>> shares an SL8500 with ACSLS with LTO 3 drives...
>>>
>>> I have define 3 library clients to 1 library manager sharing an ACSLS
>>> library... how did you define an scsi library client to to an ACSLS
>>> libray manager ¿?
>>> Could you describe more your environment ¿? How many Library managers
>>> did you have ¿? and library clients ¿? Connections ¿?
>>>
>>> Regards,
>>> Ibán.
>>>
>>> Matthias Feyerabend escribió:
>>>
>>>> Hello,
>>>>
>>>> We are using two STK Libraries L700 attached to FC with IBM-LTO1 and
>>>> IBM-LTO2.
>>>> They are defined to TSM 5.3 Library Manager (Windows) and Library
>>>> clients as scsi Libraries.
>>>>
>>>> They are used from several library clients in Windows and Linux.
>>>> Both libraries are heavily used and we are running more and more in
>>>> error situations (errors like 3e24 in fsc log) where libraries and
>>>> drives are no longer usable and only a full power cycle of the 
>>>> library
>>>> helps.
>>>>
>>>> Is there some experience that STK ACSLS software will help to 
>>>> overcome
>>>> this painfull errors ?
>>>>
>>>> As TSM has its own driver we dont really need ACSLS, but perhaps 
>>>> we get
>>>> better reliability.
>>>>
>>>> Any expertise ?
>>>>
>>>> Thank you.
>>>>
>>>> Matthias Feyerabend
>>>>
>>>>
>>>>
>>>> -- 
>>>> -- 
>>>> Matthias Feyerabend            | M.Feyerabend AT gsi DOT de
>>>> Gesellschaft fuer Schwerionenforschung    | phone +49-6159-71-2519
>>>> Planckstr. 1                | privat +49-6151-718781
>>>> D-64291 Darmstadt            | fax   +49-6159-71-2519
>>>>
>>>
>>
>>
>> -- 
>> -- 
>> Matthias Feyerabend            | M.Feyerabend AT gsi DOT de
>> Gesellschaft fuer Schwerionenforschung    | phone +49-6159-71-2519
>> Planckstr. 1                | privat +49-6151-718781
>> D-64291 Darmstadt            | fax   +49-6159-71-2519
>


-- 
--
Matthias Feyerabend                     | M.Feyerabend AT gsi DOT de
Gesellschaft fuer Schwerionenforschung  | phone +49-6159-71-2519
Planckstr. 1                            | privat +49-6151-718781
D-64291 Darmstadt                       | fax   +49-6159-71-2519

<Prev in Thread] Current Thread [Next in Thread>