Check whethe the IO slot is confiureeged coreectly, as the error message says, 
it cant move the tape from 4112 to 257, the IO and library is not able to see 
the 4112 slot correctly.

11/08/2006 13:28:10      ANR8942E Could not move volume 818ACFL2 from 
slot-element 4112 to slot-element 257. (SESSION: 7292, PROCESS: 593)

this might help you,

check the configuration of the libarary and IO slot

Regards 
Sujay Dinakar .R



----- Original Message ----
From: Paul Dudley <pdudley AT ANL.COM DOT AU>
To: ADSM-L AT VM.MARIST DOT EDU
Sent: Wednesday, November 8, 2006 8:09:34 AM
Subject: Checking in new tapes on new TSM tape library


I am trying to check in a new LTO3 tape in our new IBM 3582 TSM tape
library that was installed a month ago.



However it keeps failing. I would like to know if I am doing it
correctly before logging a fault call with IBM.

I am placing the new tape with the barcode label on it, in the IO slot
on the right side of the unit.



The command I execute is:



tsm: ANLTSM>label libvol lb1.1.0.3 818ACFL2 checkin=scratch

ANS8003I Process number 593 started.



tsm: ANLTSM>q pr



Process   Process Description    Status

  Number

--------   --------------------
-------------------------------------------------

     593   LABEL LIBVOLUME        ANR8804I Labelling volume 818ACFL2 in
library

                                   LB1.1.0.3.



tsm: ANLTSM>q req

ANR8352I Requests outstanding:

ANR8306I 153: Insert LTO volume 818ACFL2 R/W into the slot with element
number 4112

of library LB1.1.0.3 within 60 minutes; issue 'REPLY' along with the
request ID when

ready.



The error that appears in the log when it fails is:



11/08/2006 13:28:10      ANR8300E I/O error on library LB1.1.0.3
(OP=8401C058,

                          CC=314, KEY=FF, ASC=FF, ASCQ=FF,
SENSE=**NONE**,

                          Description=The source slot or drive was empty
in an

                          attempt to move a volume).  Refer to Appendix
D in the

                          'Messages' manual for recommended action.
(SESSION: 7292,

                          PROCESS: 593)



11/08/2006 13:28:10      ANR8942E Could not move volume 818ACFL2 from
slot-element

                          4112 to slot-element 257. (SESSION: 7292,
PROCESS: 593)

11/08/2006 13:28:10      ANR8802E LABEL LIBVOLUME process 593 for
library LB1.1.0.3

                          failed. (SESSION: 7292, PROCESS: 593)



Regards

Paul











Paul Dudley

ANL IT Operations Dept.

ANL Container Line

pdudley AT anl.com DOT au











ANL - CELEBRATING 50 YEARS

ANL DISCLAIMER
This e-mail and any file attached is confidential, and intended solely to the 
named addressees. Any unauthorised dissemination or use is strictly prohibited. 
If you received this e-mail in error, please immediately notify the sender by 
return e-mail from your system. Please do not copy, use or make reference to it 
for any purpose, or disclose its contents to any person.