TSM
2006-02-07 01:48:10
Hi all,
Could anyone enligthen me why the command issued below return unfavourable
results?
I have element = 262 for first command and element = 288 for second
command.
Checked that the physical slot contains element 288.
Supposingly the database should be in sync and return the same results.
Select * from drives
LIBRARY_NAME: LTOLIB
DRIVE_NAME: LTODRIVE6
DEVICE_TYPE: LTO
ONLINE: YES
READ_FORMATS: ULTRIUM2C,ULTRIU
WRITE_FORMATS: ULTRIUM2C,ULTRIU
ELEMENT: 262
ACS_DRIVE_ID:
DRIVE_STATE: LOADED
ALLOCATED_TO: KULTSM01P
LAST_UPDATE_BY: SKONG
LAST_UPDATE: 2006-01-23 14:34:23.000000
CLEAN_FREQ:
DRIVE_SERIAL:
________________________________________________________________________________________
q mount
ANR8330I LTO volume 288AHN is mounted R/O in drive LTODRIVE6 (/dev/rmt12),
status: IN USE.
ANR8330I LTO volume 237AHN is mounted R/W in drive LTODRIVE3 (/dev/rmt3),
status: IN USE.
ANR8334I 2 matches found.
Thanks and Warmest Regards,