Did you load the correct device drivers? For non-IBM libraries you must load 
the TSM Device Driver for those medium changers and
drives.


Bill Boyer
"Some days you're the bug, some days you're the windshield" - ??

-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf Of 
Reuben Pillay
Sent: Tuesday, November 22, 2005 10:25 AM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: FW: Windows Adic Scalar i2000,TSM 5.3.2

NB: This email and its contents are subject to our email legal notice which can 
be viewed at
http://www.sars.gov.za/Email_Disclaimer.pdf

----
Hi,



Corrections to earlier post.Still experiencing same problem.



Problem comes when we define the library within TSM, "define path
servername LTOLIB3 srctype=server destt=libr   device=lb5.3.0.3.
online=yes" get error I/O error accessing library LTOLIB3 RC=15





Kind Regards,

Reuben

Cell 0833218362

Office 012 422 5960

________________________________

From: Reuben Pillay
Sent: 22 November 2005 08:21 AM
To: 'ADSM-L AT VM.MARIST DOT EDU'
Subject: Windows Adic Scalar i2000,TSM 5.3.2







Hi all



Battling to define library path, Adic Scalar i2000.



We have the following configuration in our environment

TSM server 5.3.2 with TSM device drive 5.3.2

Adic Scalar i2000 firmware 300A; (windows driver version 5.2.3790.0) with 12 x 
LTO III (windows driver version 6.1.0.9)

Cisco Switch MDS 9509

Windows 2003 operating system, q logics 2340 HBA with windows device driver 
9.0.2.11.



We can pick up the library from windows 2003 as Adic Scalar i2000 (We even 
tried to configure the library as Adic Scalar  i1000) we
pick the drives as IBM Ultrium TD3 SCSI sequential device,



Problem comes when we define the library within TSM, "define path
servername LTOLIB3 srctype=server destt=libr   device=lb5.3.0.3.
online=yes" get error I/O error accessing library LTOLIB3 RC=15



Going through the wizard, we get the error message, "error obtaining the 
device" on the status field.

We managed to configure the library and use it as a manual device.



Which is the supported configuration with this implementation?



Any help on this regard will be highly appreciated.



Many thanks





Kind Regards,