Re: Strange issue with a Windows server
2005-08-01 11:44:49
Hi,
- Reset the password for this virtual node on the ITSM server;
- Log in on the active cluster controler;
- dsmc q sched -optfile=<location of the opt file of the
virtualnode>\virtualnode's optfile
- give enter for node > password just set in step 1
Also check your password synch option in the cluster administrator
This should work.
Note: if you log into your virtual machine, the password actions will
not work correctly.
Regards,
Karel
-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf Of
Kauffman, Tom
Sent: maandag 1 augustus 2005 17:22
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Strange issue with a Windows server
I Can't find anything with google, so I thought I'd hit the brain trust
here before calling it in to IBM.
We have a Windows 2000 cluster that's been working just fine for over
three years -- and then the TSM service quit responding to my server
(AIX, TSM 5.1.6.3).
To my knowledge, there has been no change on either the Windos cluster
or the TSM server -- but here's the problem report form the W2K admin:
"Looking at the server this morning, it removes the password for ADSM
from the registry when the service is started. I can perform an "update"
which places it back in the registry, but it gets removed again once the
service is started."
And, from the dsmerror.log:
08/01/2005 07:32:37 Trying port number 56582
08/01/2005 07:32:37 Obtained new port number on which to listen.
08/01/2005 07:32:37 ReadPswdFromRegistry(): getRegValue(): Win32 RC=2 .
08/01/2005 07:32:37 ReadPswdFromRegistry(): getRegValue(): Win32 RC=2 .
08/01/2005 07:32:37 ReadPswdFromRegistry(): getRegValue(): Win32 RC=2 .
08/01/2005 07:32:37 ReadPswdFromRegistry(): getRegValue(): Win32 RC=2 .
08/01/2005 07:32:37 sessOpen: Error 137 from signon authentication.
08/01/2005 07:32:37 ReadPswdFromRegistry(): getRegValue(): Win32 RC=2 .
08/01/2005 07:32:38 ReadPswdFromRegistry(): getRegValue(): Win32 RC=2 .
08/01/2005 07:32:38 sessOpen: Error 137 from signon authentication.
08/01/2005 07:32:38 ANS1029E Communications have been dropped.
Suggestions? Or do I give IBM a call?
TIA
Tom Kauffman