ADSM-L

Re: tapeutil question !

2005-07-28 12:10:24
Subject: Re: tapeutil question !
From: Sung Y Lee <sunglee AT US.IBM DOT COM>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Thu, 28 Jul 2005 12:00:25 -0400
One thing I notice..

It would appear path /dev/rmt4 has been defined to drive04 and drive05.
Each drive should only have one defined path to it.
I would double check to be sure you have current paths set for drive04 and
drive05.


Thanks,

Sung Y. Lee

"ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU> wrote on 07/28/2005
11:50:08 AM:

> Interesting. This just reminded me of a question I keep meaning to ask;
>
> Can anyone get the -f option to work for tapeutil on anything other than
> AIX?
>
> At this site the command returns with no output on either solaris / hpux
> at various code levels.
>
> It's annoying, because we have to go through the menu's when we are inq
> 83'ing drives to see WWN's, rather than being able to use a script.
>
>
> Matt.
>
>
>
>
>
> --------------------------
> Matthew Warren.
> matthew.warren AT powergen.co DOT uk
> matthew_j_warren AT hotmail DOT com
> http://tsmwiki.com/tsmwiki/MatthewWarren
>
>
> -----Original Message-----
> From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf 
> Of
> David Longo
> Sent: Thursday, July 28, 2005 2:29 PM
> To: ADSM-L AT VM.MARIST DOT EDU
> Subject: Re: tapeutil question !
>
> tapeutil -f /dev/smc0 inventory > tapelist
>
> Standard unix i.o.
>
>
> David B. Longo
> System Administrator
> Health First, Inc.
> 3300 Fiske Blvd.
> Rockledge, FL 32955-4305
> PH      321.434.5536
> Pager  321.634.8230
> Fax:    321.434.5509
> david.longo AT health-first DOT org
>
> >>> goran.k AT VIP DOT HR 07/28/05 7:28 AM >>>
> hi fellas !
> just a quick one,
> how to redirect outpur from tapeutil to a file ?
> i would like to file element inventory, thanks ...
>
> goran
> vipnet
>
> problems following, if any want to take a look
> thanks ...
>
> ANR8457I AUDIT LIBRARY: Operation for library LTO_LIB03 started as
> process
> 9.
> ANR8300E I/O error on library LTO_LIB03 (OP=00006C03, CC=207, KEY=05,
> ASC=83, ASCQ=04,
> SENSE=70.00.05.00.00.00.00.0A.00.00.00.00.83.04.42.00.00.00.,
> Description=Device is not in a state capable of performing request).
> Refer
> to Appendix D in the 'Messages' manual for recommended
> action.
> ANR8942E Could not move volume NOT KNOWN from slot-element 4096 to
> slot-element 261.
> ANR8460E AUDIT LIBRARY process for library LTO_LIB03 failed.
> ANR0985I Process 9 for AUDIT LIBRARY running in the BACKGROUND completed
> with completion state FAILURE at 11:07:18.
>
>
> ANR8470W Initialization failure on drive DRIVE04 in library LTO_LIB03.
>
> ANR8912E Unable to verify the label of volume from slot-element 16 in
> drive
> DRIVE04 (/dev/rmt4) in library LTO_LIB03.
> ANR8951I Device /dev/rmt4, volume unknown has issued the following
> Information TapeAlert: The tape in the drive is a cleaning
> cartridge.
>
> ANR8302E I/O error on drive DRIVE05 (/dev/rmt4) (OP=WRITE, Error
> Number=5,
> CC=0, KEY=0B, ASC=4B, ASCQ=00,
> SENSE=70.00.0B.00.00.00.00.0A.00.00.00.00.4B.00.00.00.00.00,
> Description=An undetermined error has occurred).  Refer to Appendix D in
> the
> 'Messages' manual for recommended action.
> ANR1411W Access mode for volume 963AGG now set to "read-only" due to
> write
> error.
>
> IBM Tape Device Error Log Analysis
> A00000
>
>
>
> NAME: rmt4   LOCATION: 20-58-0   DEVICE TYPE: 3580
>
> DATE: 07/28/05 04:54:00   SEQUENCE #26232   ERROR ID: HARDWARE ERROR
>
> SCSI CDB: 0A0004000000
>
> SCSI STATUS BYTE: CHECK CONDITION    SENSE KEY: B    ASC/ASCQ: 4B00
>
> SCSI SENSE BYTES 0-17:
>   70000B000000000A000000004B0000000000
>
> SCSI EXTENDED SENSE BYTES:
>   0000000000000000000000000000000000000000000000000000000000000000
>
>   000000000000000000000000000000000000000000000000000000000000
>
>
>
>
> NAME: rmt4   LOCATION: 20-58-0   DEVICE TYPE: 3580
>
> DATE: 07/28/05 04:53:31   SEQUENCE #26231   ERROR ID: HARDWARE ERROR
>
> SCSI CDB: 0A0004000000
>
> SCSI STATUS BYTE: CHECK CONDITION    SENSE KEY: B    ASC/ASCQ: 4B00
>
> SCSI SENSE BYTES 0-17:
>   70000B000000000A000000004B0000000000
>
> SCSI EXTENDED SENSE BYTES:
>   0000000000000000000000000000000000000000000000000000000000000000
>
>   000000000000000000000000000000000000000000000000000000000000
>
>
> Drive Address 256
>   Drive State .................... Abnormal
>   ASC/ASCQ ....................... 8300
>   Media Present .................. Yes
>   Robot Access Allowed ........... No
>   Source Element Address Valid ... No
>   Media Inverted ................. No
>   Same Bus as Medium Changer ..... Yes
>   SCSI Bus Address ............... 0
>   Logical Unit Number Valid ...... No
>   Volume Tag .................
>
> +----------------+
> |                |
> |  261 drive 3   |
> +----------------+
> |                |
> |  260 drive 2   |
> +----------------+
> |                |
> |  259 drive 6   |
> +----------------+
> |                |
> |  258 drive 5   |
> +----------------+
> |                |
> |  257 drive 1   |
> +----------------+
> |                |
> |  256 drive 4   |
> +----------------+
>
>
> is DRIVE04 faulty ?
>
> ##############################################################
> This message is for the named person's use only.  It may
> contain confidential, proprietary, or legally privileged
> information.  No confidentiality or privilege is waived or
> lost by any mistransmission.  If you receive this message
> in error, please immediately delete it and all copies of it
> from your system, destroy any hard copies of it, and notify
> the sender.  You must not, directly or indirectly, use,
> disclose, distribute, print, or copy any part of this message
> if you are not the intended recipient.  Health First reserves
> the right to monitor all e-mail communications through its
> networks.  Any views or opinions expressed in this message
> are solely those of the individual sender, except (1) where
> the message states such views or opinions are on behalf of
> a particular entity;  and (2) the sender is authorized by
> the entity to give such views or opinions.
> ##############################################################
>
>
>
> ___________________________ Disclaimer Notice __________________________
> This message and any attachments are confidential and should only be
> read by those to whom they are addressed. If you are not the
> intended recipient, please contact us, delete the message from your
> computer and destroy any copies. Any distribution or copying without
> our prior permission is prohibited.
>
> Internet communications are not always secure and therefore Powergen
> Retail Limited does not accept legal responsibility for this
> message. The recipient is responsible for verifying its authenticity
> before acting on the contents. Any views or opinions presented are
> solely those of the author and do not necessarily represent those of
> Powergen Retail Limited.
>
> Powergen Retail Ltd is authorised and regulated by the Financial
> Services Authority for the sale and service of general insurance
products.
>
> Registered addresses:
>
> Powergen Retail Limited, Westwood Way, Westwood Business Park,
> Coventry, CV4 8LG.
> Registered in England and Wales No: 3407430
>
> Telephone +44 (0) 2476 42 4000
> Fax +44 (0) 2476 42 5432

<Prev in Thread] Current Thread [Next in Thread>