Thanks for pointing me at the info,

We are still confused though, however

The Technote states that SharedMem is not valid for HP and Solaris. We
have just tested runs on an HP box with SharedMem and everything works
fine, and performs faster (..this is leading on from the other post I
have made regarding performance problems and LanFree)

This is whats confusing us. Is there a definitive answer as to which
levels of HPUX / Solaris storage agent do / do not support Sharedmem ? I
am currently grabbing and holding several README's to try and find if
HPUX had the option enabled in some release.

These are version 5.2.2 and 5.2.4 storage agents on HPUX
Clients 5.2.2 on HPUX 11i v1

Server version 5.3.4 on AIX 5.2


Matt.


-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf Of
Richard Sims
Sent: Friday, June 03, 2005 2:36 PM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: commethod sharedmem under solaris

On Jun 3, 2005, at 9:17 AM, Warren, Matthew (Retail) wrote:


> ...         Invalid entry : '   LANFREECommmethod    SharedMem'
>
> ANS1038S Invalid option specified
>
>
> If I change LANFREECOMMMETHOD to TCPIP everything is fine.
>
>
> Is SharedMem supported ?

Matt - See IBM site Technote 1164054.  They say the Readme explains.

   Richard


___________________________ Disclaimer Notice __________________________
This message and any attachments are confidential and should only be read by 
those to whom they are addressed. If you are not the intended recipient, please 
contact us, delete the message from your computer and destroy any copies. Any 
distribution or copying without our prior permission is prohibited.

Internet communications are not always secure and therefore Powergen Retail 
Limited does not accept legal responsibility for this message. The recipient is 
responsible for verifying its authenticity before acting on the contents. Any 
views or opinions presented are solely those of the author and do not 
necessarily represent those of Powergen Retail Limited. 

Registered addresses:

Powergen Retail Limited, Westwood Way, Westwood Business Park, Coventry, CV4 
8LG.
Registered in England and Wales No: 3407430

Telephone +44 (0) 2476 42 4000
Fax +44 (0) 2476 42 5432

<Prev in Thread] Current Thread [Next in Thread>