ADSM-L

Re: DISK POOL

2004-08-19 08:17:15
Subject: Re: DISK POOL
From: "Warren, Matthew (Retail)" <Matthew.Warren AT POWERGEN.CO DOT UK>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Thu, 19 Aug 2004 13:14:43 +0100
Also, has the MAXSCRATCH limit for the next stgpool been hit?

-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf Of
Bill Dourado
Sent: Tuesday, August 10, 2004 4:12 PM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: DISK POOL

.........have you tried  :

                                         q vol stgp=3494pool
access=readwrite stat=filling
                                          to make sure tapes are
available


                                         q stg 3494pool f=d
                                        check for "Maximum Scratch Tapes
Allowed"

Have you got scratch tapes available in your Library ?


Bill








"Hashim, Shukrie BSP-IMI/211" <Shukrie.Hashim AT SHELL DOT COM>
Sent by: "ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU>
10/08/2004 02:15
Please respond to "ADSM: Dist Stor Manager"


        To:     ADSM-L AT VM.MARIST DOT EDU
        cc:
        Subject:        DISK POOL


Hi there ppl,

I have a problem with my disk pool(DASDPOOL) .. i have 100% util and the
trigger ... is 30% but I dunno why it's not going to the tape
pool(3494POOL) .. and when I check the tape pool (q vol stgp=3494pool)
..
there are still alot of tapes being status FILLING ... hmmm ..

DASDPOOL      DISK          131,000.0   100.0   100.0     30     0
3494POOL

please advice ...

Shukrie


___________________________ Disclaimer Notice __________________________
This message and any attachments are confidential and should only be read by 
those to whom they are addressed. If you are not the intended recipient, please 
contact us, delete the message from your computer and destroy any copies. Any 
distribution or copying without our prior permission is prohibited.

Internet communications are not always secure and therefore Powergen Retail 
Limited does not accept legal responsibility for this message. The recipient is 
responsible for verifying its authenticity before acting on the contents. Any 
views or opinions presented are solely those of the author and do not 
necessarily represent those of Powergen Retail Limited. 

Registered addresses:

Powergen Retail Limited, Westwood Way, Westwood Business Park, Coventry, CV4 
8LG.
Registered in England and Wales No: 3407430

Telephone +44 (0) 2476 42 4000
Fax +44 (0) 2476 42 5432

<Prev in Thread] Current Thread [Next in Thread>