Re: Firmware upgrade question
2003-02-11 04:35:40
None of these. Install the latest one (D0IF_295) that fixes some nasty
problems especially if you are using ES-1000s. D0IF_26E regresses a fix
that the previous firware had for ES-1000s. There are also a lot fixes
related to bad tapes. There is a change to improve cleaning cycle needs and
to FINALLY handle the LOCATING error when a tape is damaged on the
beginning, especially new ones. We are putting this on in a few days. It
is the generally available release to a patch level we needed to reintroduce
the fix for ES-1000s.
Paul D. Seay, Jr.
Technical Specialist
Northrop Grumman Information Technology
757-688-8180
-----Original Message-----
From: Jager Frederic (BIL) [mailto:Frederic.Jager AT DEXIA-BIL DOT COM]
Sent: Saturday, February 08, 2003 4:04 AM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Firmware upgrade question
Hi,
Having a shared 3494 library with 11 3590E1A drives (7 SCSI + 4 fibre), we
were told by the CE to upgrade the firmware. We currently use DOIE_350 on
all drives. What would you recommend to install as a mandatory firmware
level (DOIF_26E, DOIA_572 or DOIB_91D) ?
NB : Library manager code level :526.05
Thanks for your answer,
Regards,
-------------------
JAGER Frédéric
---------------------
An electronic message is not binding on its sender.