ADSM-L

Re: ANR0481W error during restore

2002-11-26 04:28:34
Subject: Re: ANR0481W error during restore
From: John Naylor <john.naylor AT SCOTTISH-SOUTHERN.CO DOT UK>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Tue, 26 Nov 2002 09:24:07 +0000
Albert,
Your CommTimeOut is seriously low.
Increase it to
 CommTimeOut      3600




"Tanone, Albert" <albert.tanone AT bain DOT com> on 11/26/2002 12:44:19 AM

Please respond to "ADSM: Dist Stor Manager" <adsm-l AT vm.marist DOT edu>

To:   adsm-l AT vm.marist DOT edu
cc:    (bcc: John Naylor/HAV/SSE)
Subject:  ANR0481W error during restore



Hi all,

I am currently experiencing the above error while trying to do a point in time
restore for some directories on a Netware 5 server. We are using TSM and in the
past 24 hours, at certain point, something would simply give up and TSM will
give this error:

ANR0481W Session xx for node xx (NetWare) terminated - client did not respond
within 180 seconds.

It was actually giving up on 60 seconds but I looked up the error message and
bumped it to 180. I can't imagine this needs to go any higher. I've never had a
problem restoring so this is not the first time we've used a 60 second timeout.
Any ideas? I've eliminated a client-end issue because I've copied the
appropriate PWD and OPT file to another NW server and pretended that was out
main file server ... the restore went through about 30 mb or so before quitting
again. The most I got was last night at around 80 mb. Also, it doesn't seem to
matter which directory I'm trying to restore.

Thanks!!

Albert Tanone
Systems Administrator
Bain & Company, Inc. | Two Copley Place | Boston, MA 02116 | USA
tel: (1) 617 527 2676  fax: (1) 617 880 0676
email: albert.tanone AT bain DOT com | web: www.bain.com








**********************************************************************
The information in this E-Mail is confidential and may be legally
privileged. It may not represent the views of Scottish and Southern
Energy plc.
It is intended solely for the addressees. Access to this E-Mail by
anyone else is unauthorised. If you are not the intended recipient,
any disclosure, copying, distribution or any action taken or omitted
to be taken in reliance on it, is prohibited and may be unlawful.
Any unauthorised recipient should advise the sender immediately of
the error in transmission.

Scottish Hydro-Electric, Southern Electric, SWALEC and S+S
are trading names of the Scottish and Southern Energy Group.
**********************************************************************

<Prev in Thread] Current Thread [Next in Thread>