ADSM-L

Re: StorageTek L700E library & TSM question

2002-11-05 10:47:08
Subject: Re: StorageTek L700E library & TSM question
From: "Spearman, Wayne" <wmspearman AT NOVANTHEALTH DOT ORG>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Tue, 5 Nov 2002 10:45:32 -0500
Hi Tim,
Thanks for the reply. At your next opportunity could you confirm whether the
robot inventories the CAP when you insert a tape in it and whether this is
done before the checkin command is issued?

You help is greatly appreciated,
Wayne

-----Original Message-----
From: HEMPSTEAD, Tim [mailto:Tim.HEMPSTEAD AT READING.SEMA.SLB DOT COM]
Sent: Tuesday, November 05, 2002 10:36 AM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: StorageTek L700E library & TSM question


We have a L700 with TSM on AIX and we just put the tapes in the CAPs and
then do a checkin from bulk and then reply to the request as per normal.
Incidentally we also had major problems with our L700 like Robin has had
below.  I don't know if it would help but you could try redefining the
library device (lb0) and see if recreating that makes any difference.

Tim


-----Original Message-----
From: Robin Sharpe [mailto:Robin_Sharpe AT BERLEX DOT COM]
Sent: 05 November 2002 15:16
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: StorageTek L700E library & TSM question


Sounds like there is something wrong with your library.  We have an HP
20/700, which is a rebadged STK L700.  I'm pretty sure the robot does look
at the CAP when we put tapes in without being prompted by TSM.  We
definitely see tapes in there on the web interface, and checkins work as
expected.  Do you have one CAP or two?  We have two, and it always goes to
CAP B (the one on the right) first, for everything.  We have another 20/700
at our west coast location, and they have had lots of problems with it...
mostly robot/barcode related.  Many parts were replaced.  They went
back-level in firmware to match us.  They finally got it stable, but it
required many months and intensive involvement of HP "top gun" CE.  We
started with TSM 4.1 & upgraded to 5.1 on HP-UX server, and the 20/700
worked fone on both (there were new drivers in 5.1 for HP-UX).

Robin Sharpe
Berlex Labs



                    "Spearman, Wayne"
                    <wmspearman@NOVANTH
                    EALTH.ORG>          To:    ADSM-L AT VM.MARIST DOT EDU
                    Sent by: "ADSM:     cc:
                    Dist Stor Manager"  Subject:
                    <[email protected]        StorageTek L700E library &
TSM question
                    DU>


                    11/05/02 10:00 AM
                    Please respond to
                    "ADSM: Dist Stor
                    Manager"





Hi All,
We have a new STK L700e LTO tape library attached to a new AIX TSM server.
We are not running ACLS on the library. I can't get the library to accept
tapes via the Cartridge Access Point (CAP). We open the door, place a tape
in the slot, close the door, and run the checkin command specifying BULK.
The process ends in a failure. The robot never looks at the CAP.

When we put the tape in the CAP, the robot never inventories the CAP. I find
this odd as our IBM 3494 tape libraries always check the CAP when the door
is opened to see what has happened. STK support says their library doesn't
do this. STK support says TSM has to tell the robot to go check the CAP. I
can't find anything in the TSM books that supports this. The STK web GUI
never shows tapes in the CAP either.

Can anyone help with this dilemma?

Thanks,

Wayne Spearman
Information Technology - Software Systems Engineer
Novant Health - Central Services
Charlotte, NC
Phone:  704-384-7019
Fax:      704-316-9936
email:    wmspearman AT novanthealth DOT org



This message and any included attachments are from NOVANT HEALTH INC. and
are intended only for the addressee(s). The information contained herein may
include trade secrets or privileged or otherwise confidential information.
Unauthorized review, forwarding, printing, copying, distributing, or using
such information is strictly prohibited and may be unlawful. If you received
this message in error, or have reason to believe you are not authorized to
receive it, please promptly delete this message and notify the sender by
e-mail.

Thank you.


_________________________________________________________
This email is confidential and intended solely for the use of the individual
to whom it is addressed. Any views or opinions presented are solely those of
the author and do not necessarily represent those of SchlumbergerSema. If
you are not the intended recipient, be advised that you have received this
email in error and that any use, dissemination, forwarding, printing, or
copying of this email is strictly prohibited.

If you have received this email in error please notify the SchlumbergerSema
Helpdesk by telephone on +44 (0) 121 627 5600.
_________________________________________________________


This message and any included attachments are from NOVANT HEALTH INC.
and are intended only for the addressee(s). The information contained
herein may include trade secrets or privileged or otherwise confidential
information. Unauthorized review, forwarding, printing, copying,
distributing, or using such information is strictly prohibited
and may be unlawful. If you received this message in error, or have
reason to believe you are not authorized to receive it, please promptly
delete this message and notify the sender by e-mail.

Thank you.

<Prev in Thread] Current Thread [Next in Thread>