ADSM-L

Re: Delete DB snapshot volume

2002-06-24 10:36:31
Subject: Re: Delete DB snapshot volume
From: Fred Johanson <fred AT MIDWAY.UCHICAGO DOT EDU>
Date: Mon, 24 Jun 2002 09:34:18 -0500
That works, but it isn't in the "HELP DEL VOLH".



Quoting "Stumpf, Joachim" <joachim.stumpf AT DATEV DOT DE>:

> If you use TSM-Server 4.1.3 there is a known error with the DEL VOLHIST
> command.
> It is fixed in 4.1.5 and allows a FORCE=YES Parameter.
> 
> http://techsupport.services.ibm.com/server/390.uhuic_getrec?
args=DVsteamboat.boulder.ibm.com+DB390+DA48383+STPQ51312+USbin
> 
> -- 
> regards / Mit freundlichen Gruessen
> Joachim Stumpf
> Datev eG
> Nuremberg - Germany
> 
> 
> Tomá¹ Hrouda <throuda AT HTD DOT CZ> (Montag, 24. Juni 2002, 11:40:02, MEST):
> 
> > Don't work ... this was first I was trying. Because this is the last and
> > only one (unfortunatelly) DB snapshot volume that was created (for test
> > reasons), TSM don't allow to delete it. I know, this is due to security
> > reasons ..... but a little half-baked when you are missed. I would
> > appreciate some FORCE=YES parameter. :-((
> >  
> > Tom
> >  
> > -----Original Message-----
> > From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU]On Behalf 
> > Of
> > Seay, Paul
> > Sent: Monday, June 24, 2002 12:46 AM
> > To: ADSM-L AT VM.MARIST DOT EDU
> > Subject: Re: Delete DB snapshot volume
> >  
> >  
> > DELETE VOLHISTORY TODATE=mm/dd/yyyy TYPE=DBSnapshot
> >  
> > This will delete all DBSnapshot volumes up to the TODATE.  Once you have
> > done that the tape will scratch.  Unfortunately, you cannot specify the
> > specific volume you want to delete.
> >  
> > Paul D. Seay, Jr.
> > Technical Specialist
> > Naptheon, INC
> > 757-688-8180
> >  
> >  
> > -----Original Message-----
> > From: Toma9 Hrouda [mailto:throuda AT HTD DOT CZ]
> > Sent: Friday, June 21, 2002 5:03 AM
> > To: ADSM-L AT VM.MARIST DOT EDU
> > Subject: Delete DB snapshot volume
> >  
> >  
> > Hi all,
> >  
> > Some time ago a had performed some DB snapshot to tape due to test device
> > class definition. Now I want use this temporary tape but I can't because
> it
> > is tracked in DB ans cannot be deleted as last DB snapshot series volume.
> Is
> > any way to clear this reference adnd reuse this tape if it is 6 months
> old
> > and normal full backups are performed on daily basis?
> >  
> > Thanks
> > Tom
> > ---
> > Pxmchozm zprava neobsahuje viry.
> > Zkontrolovano antivirov}m systimem AVG (http://www.grisoft.cz).
> > Verze: 6.0.371 / Virova baze: 206 - datum vydanm: 13.6.2002
> > 
> 

Fred Johanson
<Prev in Thread] Current Thread [Next in Thread>