ADSM-L

TSM and 3583 LTO Library

2001-06-14 11:44:29
Subject: TSM and 3583 LTO Library
From: Mahesh Tailor <MTailor AT CARILION DOT COM>
Date: Thu, 14 Jun 2001 11:45:06 -0400
Hello, all!

I have just SCSI attached an IBM 3583 LTO library to my TSM server.
Installed the latest verstion of Atape and AIX recognizes the library as
follows:

rmt6 Available 10-68-00-0,0 IBM 3580 Ultrium Tape Drive
rmt7 Available 10-68-00-1,0 IBM 3580 Ultrium Tape Drive
rmt8 Available 10-68-00-2,0 IBM 3580 Ultrium Tape Drive
smc1 Available 10-68-00-6,0 IBM 3583 Library Medium Changer

Here's what I have:

Atape 6.0.4.0
AIX 4.3.2.0
TSM 3.7.4.0.
3583 firmware 2.05.0003 and sled version 2.01.0001

Once the OS recognized the library, I executed the following commands to
define the library in TSM.

DEFINE LIBRARY 3583lib libtype=scsi device=/dev/smc1
DEFINE DRIVE 3583lib RMT6 device=/dev/rmt6 element=256
DEFINE DRIVE 3583lib RMT7 device=/dev/rmt7 element=257
DEFINE DRIVE 3583lib RMT8 device=/dev/rmt8 element=258
DEFINE DEVCLASS 3580 devtype=lto format=ultriumc libra=3583lib
estcapa=100G
DEFINE STGPOOL ONSITE 3580 DESCRIPTION="3583 LTO Library"
                          ACCESS=READWRITE MAXSIZE=NOLIMIT HIGHMIG=90
LOWMIG=70
                          COLLOCATE=NO RECLAIM=100 MAXSCRATCH=999
REUSEDELAY=0
                          MIGDELAY=0 MIGCONTINUE=YES

The commands all ran successfully.  I then tried to label and checkin a
tape.  I issued the following command:

LABEL libv 3583lib search=b labels=b checkin=scr overwrite=y

I replied the REQUEST and then after about 30 seconds the command
completes without doing anything with the tape.  I get the following
entries in the actlog.

06/13/01   14:01:07      ANR8373I 003: Fill the bulk entry/exit port of
library
                          3583LIB with all LTO volumes to be processed
within 60
                          minute(s); issue 'REPLY' along with the request
ID when
                          ready.

06/13/01   14:01:11      ANR2017I Administrator ADMIN issued command: REP
003
06/13/01   14:01:11      ANR8499I Command accepted.

06/13/01   14:01:21      ANR8300E I/O error on library 3583LIB
(OP=00006C03,
                          CC=207, KEY=05, ASC=83, ASCQ=03,


SENSE=70.00.05.00.00.00.00.0A.00.00.00.00.83.03.46.00.00-
                          .00., Description=Device is not in a state
capable of
                          performing request).  Refer to Appendix B in
the
                          'Messages' manual for recommended action.

06/13/01   14:01:21      ANR9999D mmsscsi.c(11395): Could not move volume
from slot
                          16 to slot 257.

06/13/01   14:01:21      ANR8841I Remove volume from slot 16 of library
3583LIB at
                          your convenience.

06/13/01   14:01:22      ANR8802E LABEL LIBVOLUME process 47 for library
failed.
06/13/01   14:01:22      ANR0985I Process 47 for LABEL LIBVOLUME running
in the
                          BACKGROUND completed with completion state
FAILURE at
                          14:01:22.

Yes, the library is online when I do this. :-)

Has anyone seen this?  What can I do to fix the problem?  Have I missed a
step?

TIA

Mahesh Tailor
WAN Administrator
Carilion Health System
Voice: 540-224-3929
Fax: 540-224-3954