Re: Only 1 writable side in an OPTICAL CARTRIDGE
2001-02-25 14:31:35
Hernando
There is an APAR for a similar sounding problem affecting TSM Server v3.7 and
v4.1 running on AIX, Sun and NT. The README for 3.7.4.3 for AIX includes the
following reference to a fix incorporated in this PTF.
IC29245 ERROR SWITCHING TO SIDE B OF OPTICAL AND WORM MEDIA
This problem affects only two-sided OPTICAL or WORM media when
switching to side B. When backing up or archiving to optical or
WORM media and side A fills up, the backup will fail with the
following errors:
.
ANR8462I End-of-side reached for WORM volume VOL1.
ANR9999D asalloc.c(4641): Error 30 accessing volume VOL1(8),
side 1.
ANR1411W Access mode for volume OW1096 now set to "read-only"
due to write error.
...
I don't know whether a fix for TSM Server v4.1 for AIX is available yet. It may
be worth contacting Tivoli support.
Neil Schofield
The information in this e-mail is confidential and may also be legally
privileged. The contents are intended for recipient only and are subject
to the legal notice available at http://www.keldagroup.com/email.htm
Yorkshire Water Services Limited
Registered Office Western House Halifax Road Bradford BD6 2SZ
Registered in England and Wales No 2366682
|