ADSM-L

Re: An I/O error occurred while accessing stk9730

2000-12-28 21:16:02
Subject: Re: An I/O error occurred while accessing stk9730
From: David Longo <David.Longo AT HEALTH-FIRST DOT ORG>
Date: Thu, 28 Dec 2000 21:16:20 -0500
I haven't worked with these specific devices but it sounds similar to problems 
I've had with others.  I would go back to basics and check scsi cabling, 
configs (system check prior to *SM) and run any system diags you have.  I have 
had a problem different times with just a slightly loose scsi cable to my 
library or a recessed pin in a connector.

David B. Longo
Systems Administrator
Health First, Inc. I/T
3300 Fiske Blvd.
Rockledge, FL 32955-4305
PH      321.434.5536
Pager  321.634.8230
Fax:    321.434.5525
david.longo AT health-first DOT org



>>> adsm4 AT YAHOO DOT ES 12/28/00 07:16PM >>>
*The problem:
 Later install TSM 3.7.0.0 (NT 4.0 clustered) without
any trouble, we had problems to define the STK9730. We
issued the command:
        define library stk9730 libtype=scsi device=lb1.0.0.1
 Tsm reply was:
        ANR8418E An I/O error occurred while accessing
stk9730

 We checked again the library, the access door it`s
closed, obviously power on and ready...

*More Information:
 - Neither the command lbtest-dev lb1.0.0.1 obtains
the expected results. We issue command open (from
lbtest) and the answer was 'lbtest error return_error
device closed'.
 - The scsi card: Adaptec 2944 Uwide. Three scsi
devices, the library and two tapes (DLT7000) which
works correctly using NT Backup.
 - ServicePack 6 installed.
 - Latest drivers for scsi card and tapes.
 - same results obtained with other 3.7.x versions.

Does anybody knows the reason for this?

Lots of thanks.

_______________________________________________________________
Do You Yahoo!?
Consiga gratis su direccisn @yahoo.es en http://correo.yahoo.es 
<Prev in Thread] Current Thread [Next in Thread>