IMPORT
1999-12-16 16:22:41
Hi Ginny,
You need to check your file, and remove numbering - it takes the whole line
in as the volume name - and yours has line numbers on the far right that are
embedded in the file - you need to remove those and the IMPORT should work
just fine.
>>Made sense to me. I added a new devclass=cart2 with devtype=cartridge and
>>refix=adsm. I have 100 tape volumes in my export, so the first time I
>>triedthe
>>import command by manually typing in the first few volumes at the commandline,
>>and the process started fine - allocated the first volume, mounted it,started
>>reading it, etc. I then cancelled the process and entered the importnode
>>command at the command line with the vol=file:'file_name' parameter, towhich I
>>keep getting an error message ANR0599E Invalid Volume Name G1081800000100
>>specified for device class CARTRIDGE. I can't figure it out. It looks as
>>though it thinks the volume G10818(which is the first volume in the export) is
>>not defined to the storage pool forthe device class, so I also tried defining
>>all 100 volumes to devclass=cart2 andgot the same error message. I also tried
>>updating the prefix on thedevclass=cartridge to ADSM, but the prefix parameter
>>is not a valid option inthe UPDATE DEVCLASS command.
Carol Nylund
Tivoli Storage Manager Development
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- Import, Etherington, Keith (K.)
- Re: Import, Lambelet,Rene,VEVEY,FC-SIL/INF.
- Re: IMPORT, Virginia Hysock
- Re: IMPORT, Sam Sheppard
- IMPORT, Virginia Hysock
- IMPORT,
Carol Trible <=
- Re: IMPORT, Virginia Hysock
- IMPORT, Virginia Hysock
- Re: IMPORT, Sam Sheppard
- IMPORT, Carol Trible
|
|
|