mutex acquisition failure
1998-11-18 08:19:26
Hello again,
Having read the to-ask-or-not-to-ask debate ;-) I decided to ask.
Server is 3.1.1.5 / AIX 4.2.1
I enabled the Tivoli receiver (begin eventl tivoli) and it works fine.
So I wrote "TECBEGINEVENTLOGGING YES" in the server options file. When
I restarted the server some time later, it died during startup with a
core dump, an error in the AIX errorlog (errpt) and the following
messages in the dsmserv.err file:
11/06/1998 09:47:47 ANR9999D Mutex acquisition failure, errno=22;
thread 15 (tid 806314420).
11/06/1998 09:47:47 ANR7838S Server operation terminated.
11/06/1998 09:47:47 ANR7833S ADSM thread 1 terminated in response to
program abort.
and so on...
I then changed back to "TECBEGINEVENTLOGGING NO" and the server
started ok. So I can only activate the tivoli receiver in a running
server. Error 22 looks like invalid argument.
AIX errpt says "stack is unusable".
Anyone seen this?
Chris Roelofs
Mainland Sequoia
|
<Prev in Thread] |
Current Thread |
[Next in Thread> |
- mutex acquisition failure,
Chris Roelofs <=
|
|
|