ADSM-L

Write Errors at EOT

1998-02-24 04:48:35
Subject: Write Errors at EOT
From: Bjorn Sandvik <BHS AT STATOIL DOT NO>
Date: Tue, 24 Feb 1998 10:48:35 +0100
I suppose that you have DLT7000 drives.  They need to be upgraded to
microcode level 60.  That has fixed that problem for us.

Bjørn Harald Sandvik

To:       ADSM-L @ VM.MARIST.EDU
cc:        (bcc: Bjørn Harald Sandvik)
From:     BatteMR @ AUSTRALIA.STORTEK.COM @ INTERNET
Date:     23.02.98 23:04:28 MST
Subject:  Write Errors at EOT



Content-type: text/plain; charset=us-ascii


ADSM'ers,
Has anyone experienced write errors when the "End of Volume" is reached
for either Tape pools or Copy Pools?
We have received the following errors which forces the "Error State" to
yes and access mode to "ReadOnly".
************************************************************************
*********
02/24/98  05:48:55      ANR1000I    Migration process 45 started for
storage
pool BACKUPPOOL
02/24/98  05:52:02      ANR8341I    End-of-volume reached for DLT volume
DLT001
02/24/98  05:52:03      ANR1411W  Access mode for volume DLT001 now set to
"read-only" due to write error.
************************************************************************
*********
All tapes are brand new and only occurs on volumes that reach the EOT
marker.
Any advice would be appreciated.
Matthew Battersby
<Prev in Thread] Current Thread [Next in Thread>