Re[2]: MagStar drives and 3494 Library
1996-11-19 15:20:56
Unlike those who have responded so far, I have seen more than my fair
share of problems with the 3494 L10 D12 with 2 3490e drives and 4 3590
Magstar drives. The problem I am having is the 3494 gets unload
failures on the 3590 drives that results in any process running on
that drive to fail.(usually migration) IBM has been working on this
since July with no fix in sight. Do I have a LEMON or is anybody else
having similar problems?
I am also adding another ADSTAR server which will share the 3494 and
have 2 of the 4 Magstar tapes dedicated to it. Is anyone out there
sharing there 3494 between 2 Adstar servers? I would appreciate any
comments.
Thank you!
Brian Pennington
Unisys Corporation
513-872-8746 work
513-872-1048 fax
brian_pennington AT aici DOT com
______________________________ Reply Separator _________________________________
Subject: Re: MagStar drives and 3494 Library
Author: "ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU> at SMTP
Date: 11/18/96 9:55 PM
On Fri, 15 Nov 1996, Bill Koeneman wrote:
We have had a 3495 tape library with 4 MAGSTAR drives attached to a
RS/6000 in operation since April. With the exception of a problem with
one of the drives which took a while to diagnose, we have been extremely
pleased with the performance and reliability of the units. We find mount
times consistently under 30 seconds. We do not get the 30GB estimated
capacity of the tape with compression, more like an average of 10-13GB,
but we back up lots of graphics which are already stored compressed
anyway. Without any hesitation, I would highly recommend the 3494 and the
MAGSTAR drives.
Ann Slaughter
Library of Congress
Washington, D.C.
The views expressed are my own and may not reflect the views of the
Library.
> MS Mail To: X400
>
>
> >From Bill Koeneman -- Koch Industries, Wichita Kansas (koenemab AT kochind
> >DOT com)
>
> We are a prospective ADSM user (RS6000-G40,3494-L12, 2 MagStar Drives) and
> would like to get some feedback on the reliability of both the MagStar
> drives and the 3494 robotics unit. Would like to know user experiences with
> these devices (frequency of problems, time to repair, types of problems,
> shelf life of tapes etc.). Any feedback would be greatly appreciated.
>
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- MagStar drives and 3494 Library, Bill Koeneman
- Re: MagStar drives and 3494 Library, Debra Young
- Re: MagStar drives and 3494 Library, Michael Louie
- Re: MagStar drives and 3494 Library, Ann E. Slaughter
- Re: MagStar drives and 3494 Library, Pete Jackson
- Re: MagStar drives and 3494 Library, Dwight Cook
- Re[2]: MagStar drives and 3494 Library,
Brian Pennington <=
- Re: Re[2]: MagStar drives and 3494 Library, Tom Bell
- Re: Re[2]: MagStar drives and 3494 Library, Paul Zarnowski
- Re: MagStar drives and 3494 Library, Helmut Richter
- Re: Re[2]: MagStar drives and 3494 Library, Sheelagh Treweek
|
|
|