Re: VOLUMEHISTORY
1995-04-20 16:28:35
In <1995Apr20.180530.25708 AT draper DOT com>, KL2 AT cu.nih DOT gov (Bob
Klein) writes:
>I noticed in our server activity log the message:
>
>No files have been configured for automatically storing
>sequential history information.
>
>Apparently there is a parameter in the server options file,
>VOLUMEHISTORY, which can be used to provide the name of a data
>set to record this information. The problem is that I don't have
>any documentation for this.
(text ommited).
This is part of the enhanced database recovery which was added at level
0.8/1.8 of release 1 servers. It is documented in the sample element
ANR1110. If you are not the person who does the SMP for your system,
find the systems programmer who does, and ask him/her 'Where is the SAMP
element named ANR1110 stored by SMP?' Review this file for
documentation about VOLUMEHISTORY and other new commands.
To more directly answer your question, create a sequential dataset
with attributes VB-6144-1028. Add this line to the end of your ADSM
options file -
volumehistory 'full mvs datasetname'
Bill Colwell
C. S. Draper Lab
Email: BColwell AT draper DOT com
Voice: 617-258-1550
|
|
|