- 1. Re: [Veritas-bu] LTO3 connectivity Issues [NC] (score: 1)
- Author: misha.pavlov AT sgcib DOT com
- Date: Thu, 27 Mar 2008 11:08:29 -0400
- Yes. There is a bug in HP LTO3 firmware related to droped packets error recovery ( or abscense of such :-) Request a latest engineering f/w code upgrade from your vendor or HP directly. L6ES/011.995
- /lists/html/Veritas-bu/2008-03/msg00394.html (11,214 bytes)
- 2. Re: [Veritas-bu] LTO3 connectivity Issues [NC] (score: 1)
- Author: "Larry Fahnoe" <fahnoe AT fahnoetech DOT com>
- Date: Thu, 27 Mar 2008 11:04:49 -0500
- On 3/27/08, misha.pavlov AT sgcib DOT com <misha.pavlov AT sgcib DOT com> wrote: Request a latest engineering f/w code upgrade from your vendor or HP directly. L6ES/011.995 works more or less OK for
- /lists/html/Veritas-bu/2008-03/msg00400.html (10,762 bytes)
- 3. Re: [Veritas-bu] LTO3 connectivity Issues [NC] (score: 1)
- Author: misha.pavlov AT sgcib DOT com
- Date: Thu, 27 Mar 2008 12:40:25 -0400
- Nope. I did copy/paste from my Library Admin. Probably HEX and mostlikely internal release. Checked my records and see dirves I had big time issues were running: L60S/011.691 L63S/010.668 M63S/010.66
- /lists/html/Veritas-bu/2008-03/msg00401.html (10,971 bytes)
- 4. Re: [Veritas-bu] LTO3 connectivity Issues [NC] (score: 1)
- Author: "Larry Fahnoe" <fahnoe AT fahnoetech DOT com>
- Date: Thu, 27 Mar 2008 12:13:50 -0500
- Misha, Thanks for the verification on version info. I'm assuming you also have an SSO environment. How many hosts participate and what OS are they? We have a small environment, 3 media hosts (2 Solar
- /lists/html/Veritas-bu/2008-03/msg00402.html (10,320 bytes)
- 5. Re: [Veritas-bu] LTO3 connectivity Issues [NC] (score: 1)
- Author: Justin Piszcz <jpiszcz AT lucidpixels DOT com>
- Date: Thu, 27 Mar 2008 13:08:11 -0400 (EDT)
- We're using M21S and we plan to upgrade to M63S next week. _______________________________________________ Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu http://mailman.eng.auburn.edu
- /lists/html/Veritas-bu/2008-03/msg00403.html (12,117 bytes)
- 6. Re: [Veritas-bu] LTO3 connectivity Issues [NC] (score: 1)
- Author: misha.pavlov AT sgcib DOT com
- Date: Thu, 27 Mar 2008 13:33:28 -0400
- That's correct, Larry - SSO and in-line copy. Two locations. 2 L700 libraries, 4 Solaris 8 media servers. One STK libray and two 2 Solaris 8 media servers writing localy at each location and doing in
- /lists/html/Veritas-bu/2008-03/msg00404.html (10,950 bytes)
This search system is powered by