Author: "David M. Hendrix" <dmhendri AT FEDEX DOT COM>
Date: Wed, 29 Mar 2000 10:40:27 -0600
Okay, let's clarify. 3590 through some sort of FC/SCSI bridge. 3590 does not have a native FC interface yet so it was assumed this config would be used. David "Burton, Robert" <ROBERT.BURTON AT ROYAL
Author: "Joshua S. Bassi" <jbassi AT GLORYWORKS DOT COM>
Date: Wed, 29 Mar 2000 10:16:47 -0800
David You are correct, 3590s are Fibre Channel supported through the IBM SAN Data Gateway (OEMed from Pathlight I think it was). I have sent out a couple of SAN proposals to for a couple of customer
Author: "David M. Hendrix" <dmhendri AT FEDEX DOT COM>
Date: Wed, 29 Mar 2000 12:54:56 -0600
Interesting. I did not know IBM was OEMing pathlight. I currently am testing with a Crossroads but hear the pathlights have better throughput. Since IBM will be reselling McData switches now, they sh
We've got a customer in Switzerland that's got the following configuration working: 1) RS/6000 running AIX 4.3.3 - the application is Veritas 2) Emulex HBA #6227 from IBM 3) Connectivity through one
Author: Mark Owens <Mark_Owens AT PRODIGY DOT NET>
Date: Thu, 30 Mar 2000 12:25:30 -0500
Keith, Would you know if the customer is using 64 bit extensions with AIX 4.3.3. We testing a similar config but the 64 bit extensions forced us to use Cambex instead of Emulex. Emulex does not have