Author: Murray Dietrich <murray.dietrich AT GOV.AB DOT CA>
Date: Tue, 5 Nov 2002 11:49:07 -0500
I am experiencing exactly the same problem as Jeff was a couple of years ago. I run the same software (5.5.3) and use the same hardware right down to the SCSI cards and am experiencing the same sympt
cable length? I've seen that with cables. Shaun -- Note: To sign off this list, send a "signoff" command via email to listserv AT listmail.temple DOT edu or visit the list's Web site at http://listma
Author: "Faidherbe, Thierry" <Thierry.Faidherbe AT HP DOT COM>
Date: Tue, 5 Nov 2002 22:13:54 +0100
I also saw that with a bad/dead terminator with a lot of activity on the bus. No CRC with less activity on the SCSI bus. Look at or Xcheck the scsi bus terminator & length. HTH, Thierry Kind regards
Author: Murray Dietrich <murray.dietrich AT GOV.AB DOT CA>
Date: Wed, 6 Nov 2002 10:48:12 -0500
Jeff (the poster of the question last year) has supplied the response below. In the meantime, I'm replacing cables and terminators as per the other posts received on this issue. I'll see what that do