Author: Ralph Cunnington <Ralph.Cunnington AT bib DOT de>
Date: Wed, 26 Mar 2014 21:09:21 +0100
Hi bacula-users, hi Ken, giving Bacula 5.2.13 on SuSE 13.1, 4 Clients on SuSE SLES11 SP1 where is the trick getting automatic Volume Labeling to work ? I've tried 3 variations as you see in Pool conf
Author: Bill Arlofski <waa-bacula AT revpol DOT com>
Date: Wed, 26 Mar 2014 16:35:34 -0400
Hi Ralph After modfying your pool configuration(s) did you remember to update the db with your new pool settings in bconsole? in bconsole do: reload (to have bacula dir re-read and apply new settings